Installation, Operating and Maintenance
Instructions blueMatic EAV
No.
Description
1
Sash part seperable cable transition KÜ-T1-SOMMER-EAV * (with 5-pole plug for receiver ENTRAsys FD)
2
Frame part STV-KÜ-T1 RT Kabel 4M
3
Connecting cable 3 m, 3-wire for motor
4
Motor housing EAV
5
Fingerprint ekey ENTRAsys FD (or other access control company Sommer)
6
Radio receiver ENTRAsys FD (company Sommer)
7
Connection cable from receiver to fingerprint scanner ENTRAsys FD (company Sommer)
*
at shipment Winkhaus STV-KÜ-T1 SET FT ZK-SO+EAV FT1M+KABEL3M
**
at shipment Winkhaus, unmounted, for retrofitting mechanical locking system
***
at shipment Sommer
Figure 3.6.4-1: Wiring blueMatic EAV and Fingerprint Sommer ENTRAsys FD (sash side)
Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen
Subject to technical changes
*
(with 3-pole plug for receiver ENTRAsys FD)
**
47
***
***
B3
B2
B1: Connection from sash part
cable transition to the
radio receiver ENTRAsys
FD (plug-in, 5-pole plug)
B2: Connection from radio
receiver ENTRAsys FD to
the motor housing EAV
(plug-in, 3-pole plug)
B3: Connection from radio
receiver ENTRAsys FD to
the fingerprint ENTRAsys
B1
FD (plug-in)
Detail A: ENTRAsys FD radio receiver
white + 12 V DC
brown 0 V
green
yellow
grey
pink
green/yellow = input for external potential-
free contact (e. g. unlocking via
intercom/open button)
NOTICE!
max. 40 m extendable
Detail B: Connections frame part STV-KÜ-T1 RT
Kabel 4M or signal line frame power supply 12 V DC
Print-no. 504 474 4
01/2017
General
information
Important
information
***
Product
description
Installation
Operation
Programming
Maintenance
and care
Errors
Troubleshooting
Technical
specifications
}
external opening signal
}
free
Accessories
www.winkhaus.de
EN
1
2
3
4
5
6
7
8