Installation, Operating and Maintenance
Instructions blueMatic EAV
3.6.4
1
Prerequisites for installation
•
The applied fingprint ENTRAsys FD has to be installed into the door sash.
•
If parallel to the fingerprint another open signal (potential-free signal: e.g. "Open"
2
button, intercom, ...) should be used for unlocking, this is possible via the frame
part STV-KÜ-T1 RT KABEL 4 M 2 or frame part STV-KÜ-T1 RT KABEL 0,6M RNT +
frame power supply STV-NETZTEIL RAHM. 12 V DC 1,5 A (2 A/2 S) 8 possible. (see
3
detail B è wires green / yellow)
•
The plugs are protected against polarity reversal and (by right assembly) against
independently solve.
4
Installation sequence
1. Plug-in the cable of the sash part cable transition KÜ-T1-SOMMER-EAV FLÜGEL-
5
TEIL 1 with 5-pole plug at the receiver ENTRAsys FD 6 .
2. Assembly connection between receiver ENTRAsys FD 6 and fingerprint ENTRAsys
FD 5 via connection cable Sommer 7 with both sided 2-pole plugs.
6
3. Assembly connection between receiver ENTRAsys FD 6 and motor housing EAV
4 . For this connect the wires of the included 3 m cable Sommer 3 and put the
3-pole plug into the receiver ENTRAsys FD (see detail A). After that put the blue
7
plug into the motor housing EAV 4 .
CAUTION!
8
With the combination blueMatic EAV + access control, the power requirement must
not to be fraught more than 2 A!
With the combination with frame power supply STV-NETZTEIL RAHM. 12 V DC the
power supply should be charged max. permanently with 1,5 A and max. 2 A will be
charged for 2 s!
NOTICE!
Receiver ENTRAsys FD, fingerprint ENTRAsys FD, connection cable Sommer in stan-
dard shipment by Sommer.
Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen
Subject to technical changes
Non-Winkhaus access control system fingerprint
Sommer ENTRAsys FD
46
Print-no. 504 474 4
01/2017
www.winkhaus.de