The DMX signal is connected to the master fixture.The message "MAst" starts fast flashing and after 20s
error massage "MA.Er" appears on its display and the fixture automatically will be switched to its DMX
address (master address is disabled).
Now the fixture has these address setting: "dM.Ad."-menu.........A017 ("A017"/" MA.Er" flashing)
If the fixture is set as the slave and DMX signal is connected to its input, the fixture will respond to DMX
signal from the controller (in dependence on the fixture's DMX address).
- Slave control
This function allows you to control the slaves from the master's control panel in a master/slave operation.
Select this function from the main menu and press [Enter]-button. Browse the list of all connected slaves
("SL.C.1" - "SL.C.9") by pressing [Up] or [Down] button. Select the desired slave and press [Enter]-
button.The slave's control panel is available from the master's control panel.
- Fixture information
The menu allows you to read an useful information about the fixture as the lamp life, head temperature,
software version, etc.
Press [Up] and [Down] buttons to select the desired option and press [Enter] to see the value or next
submenu.
- Power On time
- By this option you can read the total number of the operation hours since the MH-660 has
been fabricated. Press [Enter] or [Mode] to return to the menu.
- The number of the hours that the MH-420 has been powered On since the counter was last
reset. Press [Enter] or [Mode] to return to the menu. In order to reset this counter to 0, you have to
hold the [Up] and [Down]-button and press the [Enter]-button.
- Lamp On time
- By this option you can read the total number of the lamp's operation hours since the MH-420
has been fabricated. Press [Enter] or [Mode] to return to the menu.
- The number of the hours that the lamp has been powered On since the counter was last
reset. Press [Enter] or [Mode] to return to the menu. In order to reset this counter to 0, you have to
hold the [Up] and [Down]-button and press the [Enter]-button.
- Lamp strikes
- By this option you can read the total number of lamp strikes since the MH-420 has been
fabricated. Press [Enter] or [Mode] to return to the menu.
- The number of lamp strikes since the counter was last reset. Press [Enter] or [Mode] to
return to the menu. In order to reset this counter to 0, you have to hold the [Up] and [Down]-button
and press the [Enter]-button.
- DMX values
Readout DMX values of each channel received by the fixture. Use the [Up] and [Down] keys to select
desired channel and press [Enter] to read its value coming to the fixture or [Mode] to cancel and return to
the menu.
"MA.SL."-menu.........d.AbL.