Operating Conditions - WIKA IV10 Mode D'emploi

Vannes d'arrêt et manifold
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Specifications

Operating conditions

Sealing material
PTFE
Graphite
Sealing material
PTFE
Graphite
The minimum design temperature is -54 °C (-65 °F).
For permanently low operating temperatures of ≤ -54 °C (≤ -65 °F), a
special design is required.
The following diagram must be used to ensure that the permissible
pressure-temperature rating is met during operation depending on the
sealing material used.
For further specifications see data sheets AC 09.19, AC 09.21,
AC 09.23.
WIKA operating instructions, shut-off valves and valve manifolds
Max. permissible operating pressure in bar
at temperature in °C
689 bar at 38 °C
276 bar at 204 °C
420 bar at 38 °C
209 bar at 538 °C
Max. permissible operating pressure in psi
at temperature in °F
10,000 psi at 100 °F
4,000 psi at 400 °F
6,000 psi at 100 °F
3,030 psi at 1,000 °F
EN