2.2.7. aSCII RS485 RECEIVER VERSIOn

Connect the asCii code by following the following table:
Connect the clock to the mains.
Change the switch position on the back onto the "On" position.
3 to 4 minutes after receiving the code, are positioned according to the
a/ Gorgy timing Protocol
Receiver mode
in this mode the clock is running in standalone mode but sets the time earlier com-
pared with the asCii code received (confguration: 2400 bits, format 8 bits, parity
pair, 1 stop bit).
The time information is in the form below:
StX
D
a
Y
10D
Byte nr
Field
Size
1
StX
2,3,4
D,a,Y
5
6,7
10D,D
8
/
9,10
10M,M
11
12,13
10Y,Y
14,15
16,17
10h,h
18
19,20
10m,m
21
22,23
10S,S
24
CR
32
Green wire
Brown wire
White wire
The hands are positioned at 12 o'clock and then,
received time information.
D
/
10M
M
Value/Meaning
1
Start of text ($02) – mark the beginning of the frame.
the day in the week in a human-readable way (MOn, tUE, WED, thU, FRI,
3
Sat, SUn for Monday to Sunday)
1
Space character ($20)
2
Day in the month on two aSCII characters ($30,$31 to $33,$31)
1
Forward slash character ($2F)
2
Year on two aSCII characters ($30,$30 for 2000 – $39,$39 for 2099)
1
Forward slash character ($2F)
2
Year on two aSCII characters ($30,$30 for 2000 – $39,$39 for 2099)
2
two Space characters ($20)
2
hours on two aSCII characters ($30,$30 to $32,$33)
1
Colon character ($3a)
2
Minutes on two aSCII characters ($30,$30 to $35,$39)
1
Colon character ($3a)
2
Seconds on two aSCII characters ($30,$30 to $35,$39)
1
Carriage Return ($0D) – mark the end of the frame
GnD
RX-
RX+
/
10Y
Y
10h
h
: 10m
m
: 10S
S
MDE-HANDI-2078V2.0
CR