Fault
The thread on the stud is
en
damaged
Stud doesn't hold in the base
material
Piston jams in the piston guide
Trigger can't be pulled
12
Printed: 20.08.2013 | Doc-Nr: PUB / 5069825 / 000 / 02
Possible cause
Fastener guide damaged
■
Steel base material too thin
■
(< 8 mm)
Hole damaged or previously used
■
Driving power too low
■
Hole not deep enough
■
Wrong drill bit used
■
Dirt/debris in hole
■
Damaged piston
■
Carbon build-up
■
Tool not pressed fully against the
■
work surface
Piston fitted incorrectly
■
Tool defective
■
Remedy
Replace the fastener guide.
■
Drive studs only on steel base
■
material ≥ 8 mm.
Drill new hole.
■
Increase driving power.
■
Drill to correct depth
■
=> visible ring
.
Use correct drill bit
■
Remove liquids, debris or other
■
foreign matter from the hole
before installing the stud.
Remove the cartridge strip
■
Piston guide
■
Check the piston and replace it if
■
necessary
■
Clean the tool
■
Press the tool fully against the
work surface.
■
Fit the piston correctly.
■
Contact your Hilti Center.