Sirius SILT26 Instructions D'utilisation Et Avis De Montage page 17

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Learni i ng the new transmi i ssi i on code:
Once the transmission code is changed in the radio
control unit, the electronic central unit of the cooker
hood must be made to set the new code in the fol-
lowing way:
Press the main power-off button of the hood and
then restore power to the electronic control unit.
Within the next 15 seconds, press the Li i ght Button
to synchronise the central unit with the code.
Reset of the Factory confi i gurati i on:
To restore the Factory configuration, follow the pro-
cedure described below: press simultaneously but-
tons
for 2 seconds. When Leds light on, press buttons
(within 5 seconds). Leds flashing 6 times indicate
the procedure is completed.
WARNING! This operation deletes permanently the
preset codes.
Emergency button:
In the event that the radio control does not work, use
the emergency button to switch the appliance off.
After any necessary repairs have been performed,
reset the emergency button.
W
ARNI I NG
The battery should be replaced every year to guar-
antee the optimal range of the transmitter.
To replace the exhausted battery, take the plastic
lid off, remove the battery and replace it with a new
one, observing the correct battery polarities.
Used batteries should be discarded in special col-
lection bins.
The below product:
RC001 Radi i o Control l
complies with the specifications set out in the
R&TTE Directive 99/5/EC.
WARNING
Any adjustments or modifications which have not
been expressly approved by the holder of the legal
conformity certificate may invalidate the user's
rights relating to the operation of the device.
Rev. 0 2 6/08/14
TIMING
As a result of the new EU65 "Energy label" and
EU66 " Ecodesign" regulations issued by the
European Commission, which came into force
as from January 1st, 2015 , our products have
been adapted to comply with these new re-
quirements.
All of the models complying with the energy
label requirements, are equipped with new
electronics including a timer device for suc-
tion speeds control, when the air capacity ex-
ceeds 650m³/h.
Internal motor models, with maximum air
capacity higher than 650m³/h, are equip-
ped with a timer device that automatically
switches the suction speed from 4th to 3rd
speed, after 5 minutes operation.
External motor models are equipped with re-
mote motors that , as for internal motor ver-
sions, include a timer device that switches
down the suction speed when it exceeds 650
mᵌ/h. (See External Motors Instructions ).
Remote motors, whose air capacity exce-
eds 650m³/h at both 4th and 3rd speed, will
have the following by default timer control
functions: The suction speed is automatical-
ly switched from 4th to 2nd speed, after 6
minu tes operation.
If the appliance is working at 3rd speed, it
is automatically switched to 2nd speed, after
7 minutes operation. Operation speeds can
also be changed during operation.
The energy consumption of the appliance in
stand – by mode is lower than 0.5W.
17

Publicité

Chapitres

Table des Matières
loading

Table des Matières