Reassemble Fireplace
Reverse all the previous steps taken in the previous
section, Prepare the Appliance, on page 2.
Consult the appliance`s Installation Manual for full
details of the above steps.
Adjust the air shutter
Once the burner module reinstalled, the air shutter is at
the left of the fi rebox.
1. Locate the aeration adjustment lever.
2. Adjust the aeration lever as required. Depending on
fuel bed used, altitude and other considerations, the
fl ame picture may be improved by adjusting the
aeration. The need for adjustment should be
determined only by operating the appliance with the
fuel bed, liners and window installed and evaluating
the fl ame picture after a 15-minute warm-up.
Airshutter open
Airshutter closed
Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication.
Designed and Manufactured by / for
Miles Industries Ltd.
190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1
Tel. 604-984-3496 Fax 604-984-0246
www.valorfi replaces.com
6
Fit the Specifi cations Label
1. Complete the required details of the new label:
"This appliance was converted on... by..." etc.
2. Fit the conversion label with new specifi cations over
the corresponding specifi cations on the data plate
attached to the fi replace at right hand side between
the fi rebox and the outer case of the appliance.
3. Complete the fi replace installation.