Télécharger Imprimer la page

Valor G4 780MNGK Manuel D'installation page 2

Publicité

General Notes Regarding Conversion
The conversion may be done before or after the
appliance is installed into the cavity. However, if the unit
has been installed, it must be removed from the cavity
(see below). Also, the gas must be connected to set the
manifold pressure.
Prepare the Appliance
 Note
Consult your Installation Manual for details on the
steps in this section.
1. Locate gas shut off valve and isolate gas supply.
2. Remove any installed trims, fronts, and doors.
3. Remove the window.
4. If the fi replace is already installed:
a. Remove the fuel bed. Be careful with fuel bed
as components are fragile.
b. Remove liner panels.
c. Disconnect the exhaust slide screws (2 screws
at top front of unit).
d. Pull the unit out while disconnecting the
exhaust slide. Leave the vents and slider
hanging in the chimney.
2
5. Remove left shroud (2 screws).
6. Remove the side cover (2 screws at left, 3 at the
front).
7. Remove burner cover (2 screws).

Publicité

loading

Ce manuel est également adapté pour:

G4 780mpgkG4 780mnG4 780mp