INSTALLATION INSTRUCTIONS
720SWK-M Sidewall Co-Linear Terminal Kit
Use with Valor models G3 739M and 739V Fireplaces ONLY
 WARNING
If these instructions are not followed
exactlly, a fire or explosion may result
causing property damage, personal
injury or loss of life.
Please leave this manual with the homeowner.
Overview
The 720SWK-M Sidewall Co-Linear Terminal Kit allows
approved Valor units listed above only to be vented
using approved 3-inch flexible vent liners to penetrate
an existing masonry solid-fuel burning fireplace and
connect to 720SWK-M horizontal termination rather than
a vertical termination at the top of the chimney.
Use of this kit requires the vent collar slider plate to be
replaced with a vent slider plate having no restrictor
(4001133), supplied with this kit except where more than
10'-0" vertical vent run.
Kit Contents
• Sidewall terminal
• Vent slider plate with NO restrictor 4001133
4006423-03
©2022, Miles Industries Ltd.
720SWK-M
This kit must be installed or serviced by a
qualified installer, service agency or gas
supplier. These instructions are to be used
in conjunction with the main installation
instructions for the above listed models.
Sidewall terminal
Front
Vent slider plate with NO
restrictor 4001133
Kit content
3"
intake
exhaust
Rear
3"

Publicité

loading

Sommaire des Matières pour Valor 720SWK-M

  • Page 1 INSTALLATION INSTRUCTIONS 720SWK-M 720SWK-M Sidewall Co-Linear Terminal Kit Use with Valor models G3 739M and 739V Fireplaces ONLY  WARNING This kit must be installed or serviced by a qualified installer, service agency or gas If these instructions are not followed supplier.
  • Page 2 The 739MN/MP and 739VN/VP appliances are supplied with the AutoFire vent collar slider plate having an integral restrictor built-in. When using the 720SWK-M Sidewall Kit, the vent collar slider plate must be replaced with one having no restrictor (see instructions below).
  • Page 3 Prepare existing masonry fireplace Install terminal A few points must be considered before inserting the Considerations gas fireplace into an existing fireplace cavity. Verify • Intake and exhaust liners must correspond between the structural integrity of the existing fireplace before heater and sidewall termination.
  • Page 4 6. Connect the liners to the collars on fireplace using 3 screws per liner or gear clamps. Ensure the exhaust liner is connected to the exhaust collar. 7. Continue with the fireplace installation according to the manual provided with the fireplace. Description Part Numbers Sidewall termination...
  • Page 5 GUIDE D’INSTALLATION 720SWK-M 720SWK-M Sortie d’évacuation colinéaire murale Utilisez avec les foyers Valor G3 739M et 739V SEULEMENT  AVERTISSEMENT Cette trousse doit être installée et entretenue par un installateur qualifié, Si les instructions fournies dans le une agence de service certifiée ou un présent guide ne sont pas suivies...
  • Page 6 Les appareils 739MN/MP et 739VN/VP sont fournis avec une plaque d’évent AutoFire possédant un restricteur intégré. Lors de l’utilisation de la Sortie d’évacuation murale 720SWK-M, la plaque d’évent doit être remplacée par la plaque d’évent sans restricteur fournie (voir instructions ci- dessous).
  • Page 7 Préparez le foyer de maçonnerie existant Fixation de la plaque de conversion au foyer existant (la plaque est fournie avec le foyer 739) Certains points sont à considérer AVANT D’INSTALLER Fixez la plaque de conversion « Ce foyer a été le foyer à...
  • Page 8 2. Faites une installation préliminaire des conduits souples de 3 pouces certifiés en les passant par le registre existant et à travers le trou percé dans le mur extérieur de maçonnerie en prenant soin de laisser assez de longueur à l’extérieur pour le raccordement à...

Ce manuel est également adapté pour:

G3 739mG3 739v