Technical Specifications - BS Charger BS60 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
TEMPERATURE & SAFETY PROTECTION
INTERNAL OVERHEAT PROTECTION: the charger has a built-in overheat and an overload protection. This protects the charger
from being damaged if overheated or overloaded and will automatically decrease the charging current. Once the unit's internal
temperature decreases to a safe level, the charger will resume normal charging.
SAFETY TIMER PROTECTION: the charger has safety timers for every stage. If the battery voltage doesn't reach a certain vol-
tage within a certain amount of time, the unit will stop charging as it's highly likely that you're attempting to charge a severely
discharged or heavily sulphated battery. If any of the stages time out, the charger will immediately stop charging in order to
protect the battery. This will be indicated with the ERROR LED flashing slowly.
REVERSE POLARITY: the charger has a reverse polarity protection. If the charger output leads are connected with a reverse po-
larity, the ERROR LED will light on and the charger will be disabled. Simply unplug the charger from AC power and then connect
the output leads to the correct polarity.
SHORT CIRCUIT PROTECTION: the charger will automatically turn off if the output leads are short circuited and the ERROR LED will
light on. This prevents the charger from being damaged if the positive and negative crocodile clips or the optional ring terminals
accidently touch each other while the charger is turned on.
ECO MODE: this battery charger has a built in ultra-low power consumption circuit. If AC power is connected and the battery is
disconnected, after 10 seconds the charger will automatically go into an ECO mode. During this mode the power drawn is less
than 0.36W which totals 0.01kWh per day power consumption. If AC power is connected and the battery is connected, once the
battery is fully charged and during the long term maintenance stage, the total power consumption is around 0.03kWh per day.
Both the selected charge rate and battery type LED's will flash GREEN to indicate ECO mode.
BATTERY TYPES & CAPACITY
Suits 12V conventional lead acid batteries (VRLA) AGM, Calcium, Gel & Wet. The Ah (Ampere Hours) capacities shown below are to
be used as a general guide only. Some batteries may be able to handle a higher charge current. Refer to the battery manufacturer's
specifications and recommendations for your charging requirements.
Charge Rate:
charging
3-20Ah
Maintaining
<100Ah
ELECTRICAL PARTS & ACCESSORIES
AC Power Cord
1.8m with 2 Pins Plug
DC Output Lead
1.2m with quick connect
Charging Leads
Quick connect 60cm with Crocodile Clips + Quick connect 60cm with fused ring terminals

TECHNICAL SPECIFICATIONS

Output
Input voltage
Input frequency
Charge voltage
Equalizing Voltage
| www.bs-battery.com
1A
4A
12-80Ah
<120Ah
6A @ 12V
100-240Vac/1.4A (95W)
50-60Hz
Gel - 14.1V
AGM & WET - 14.4V
Calcium - 14.7V
Gel - 14.3V
AGM & WET - 14.6V
Calcium - 15.5V
6A
18-120Ah
<180Ah
Float voltage
Start voltage
Operating temperature
Storage temperature
Operating humidity
Size (LxWxH)
Weight
Approvals
13.6V
3V
-15 to 50° C
-25 to 85°C
90% RH Max.
182x88x48 mm
0.75kg
CE