Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8

CHARGING CURVE

Initial qualification: test automatically battery condition and determine if chargers engages rejuvenation or charging cycle.
Rejuvenation: rejuvenates sulphated batteries with a high frequency pulse.
Soft start: increases battery life by gently starting to charge the battery.
Bulk charge: reduces charging time by delivering maximum charge to set voltage.
Absorption: ensures a full charge to the battery without overcharging.
Equalization: returns a full hydrometer reading to calcium batteries by removing acid stratification.
Battery test: tests the battery to ensure fully charged.
Float: float charge maintains the battery at 100% charge. 21 days restart.
Long term maintenance: if the battery voltage sinks, the special pulses will keep the battery in optimal states.
TROUBLE SHOOTING
PROBLEM
INDICATION
Charger
No Indicator
does not work
lights on
Charger
Error Red LED is
has no DC output
ON
No charging
Error Red LED is
current
Flashing
The full/float light
Error Red LED is
won't come on
Flashing
or
Full Charge Green
LED is Flashing
| www.bs-battery.com
POSSIBLE CAUSES
-
No AC power
-
Output is short circuited
-
Reverse polarity protection
-
Loose / bad connection to
the battery
-
Battery is severely sul-
phated
-
Battery has a damaged cell
-
Overheat protection mode
-
Battery Ah capacity too
large for the battery char-
ger and it has time out
-
Battery is defective
-
Battery is severely sul-
phated
SUGGESTED SOLUTION
-
Check AC connections and make sure the AC Power
supply is switched ON
-
Try a different AC Power supply which you know is
working
-
Check DC connections between charger and battery
and make sure they are not short circuited. (Touching
each other)
-
Check that the crocodile clips have not fallen off or
come loose
-
Check that the crocodile clips/ ring terminals are
connected with the correct polarity
Note: the charger output current is only present when
connected to a battery
-
Check the battery condition, age etc.
-
Battery may need replacement
-
Move battery & charger to a cooler environment
-
Check that the charger specifications match the batte-
ry capacity. E.g. make sure that the battery capacity is
not too big for the charger
-
Battery may need replacement
-
The selected charge rate might be too low for the bat-
tery. Switch charger off and on and try again or try a
higher charge rate setting. Make sure it doesn't exceed
the maximum charge limit for your battery
7

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières