Accessory alarm device
The alarm device signals an excessive
high water level. It can be installed sub-
sequently. The cable is pulled through
the vent pipe and sealed in the same
way as the pump cable. The alarm unit
should be connected to a separate elec-
tric circuit, to ensure the operation in
case of a pump fault. Alternatively it can
be equiped with our 9V-rechargeable
battery for off the line operation.
Accessory special ventilation
If the ventilation over the roof level is not
possible, alternatively the special venti-
lation consisting of a ventilation screen
and 3 activated carbon filters can be in-
stalled with a T-piece in the cable pipe.
MAINTENANCE
The tank, the float switches and the foot
strainer of the pump should be inspect-
ed regularly and cleaned if necessary.
To service the pump, please refer to the
separate operating instruction.
ATTENTION! Always grease the screws
before using them to close the cover
plate and ensure the correct position of
the profiled seal.