9.0 FIRST START UP MODELS WITHOUT STARTER
(7-12-16-20-30-20ELEK.-30ELEK.)
After following all the above instructions proceed as follows:
1. Check that the mains voltage corresponds to the nominal one of the battery
charger indicated on the plate.
2. Disconnect the cables connected to the positive pole (+) of the battery.
3. Untighten the caps of the battery and check the level of the electrolytic liquid.
4. Connect in sequence:
- the red clamp to the positive pole (+)
- the black clamp to the frame of the car, away from the battery and from the
fuel pipe.
5. Find out the voltage of the battery to be charged (12 or 24 V) and position the
proper commutator of the battery charger on the same value.
6. Start the battery charger, check the position which the indicator of the
ampmeter will acquire.
7. Adjust the charging current with the proper commutator.
8. To interrupt the charge, disconnect in sequence:
- the supply cable
- the negative conductor (-)
- the positive conductor (+)
9.1 FIRST START UP MODELS WITH STARTER
After following all the above instructions proceed as follows:
CHARGE
1. Check that the mains voltage corresponds to the nominal one of the battery
charger indicated on the plate.
2. Disconnect the cables connected to the positive pole (+) of the battery.
3. Untighten the caps of the battery and check the level of the electrolytic liquid.
4. Connect the black cable to the negative attachment of the battery charger with
the inscription (-CHARGE).
5. Find out the voltage of the battery to be charged (12 or 24 V) and connect the
red cable to the corresponding attachment (+12 V) or (+24 V).
6. Connect in sequence:
- the red clamp to the positive pole (+)
- the black clamp to the frame of the car, away from the battery and from the
fuel pipe.
7. Start the battery charger; check the position which the indicator of the
ampmeter will acquire.
8. Adjust the charging current with the proper commutator.
9. Connect the input cable to the mains 230 V.