Installation and connection
Product can only be installed and connected in
accordance with the statutory installation rules.
Do not install the product next to
irefrigerators or freezers. The heat emitted
7
by the product will increase the energy
consumption of cooling appliances.
e
Carry the product with at least two persons.
e
Product must be placed directly on the floor.
It must not be placed onto a base or a
pedestal.
Do not use the door and/or handle to carry
gor move the product. The door, handle or
hinges get damaged.
Electrical connection
Connect the product to a grounded outlet/line
protected by a fuse of suitable capacity as stated
in the "Technical specifications" table. Have the
grounding installation made by a qualified
electrician while using the product with or
without a transformer. Our company shall not be
liable for any damages that will arise due to
using the product without a grounding installation
in accordance with the local regulations.
\ The product must be connected to the
mains supply only by an authorised and
qualified person. The product's
warranty period starts only after correct
installation.
Manufacturer shall not be held responsible
for damages arising from procedures
carried out by unauthorised persons.
_DANGER:
The power cable must not be clamped,
bent or trapped or come into contact
with hot parts of the product.
A damaged power cable must be replaced
by a qualified electrician. Otherwise, there is
risk of electric shock, short circuit or fire!
The mains supply data must correspond to the
data specified on the type label of the product.
The rating plate is either seen when the door or
the lower cover is opened or it is located at the
rear wall of the unit depending on the unit type.
Power cable of your product must comply with
the values in "Technical specifications" table.
electrical installation, disconnect the
product from the mains supply.
There is the risk of electric shock!
Connecting the power cable
1. If itis not possible to disconnect all poles in
the supply power, a disconnection unit with
at least 3 mm contact clearance (fuses, line
safety switches, contactors) must be
connected and all the poles of this
disconnection unit must be adjacent to (not
above) the product in accordance with IEE
directives. Failure to obey this instruction
may cause operational problems and
invalidate the product warranty.
Additional protection by a residual current circuit
breaker is recommended.
i a Cable is supplied with the product:
TERMINAL BLOCK
BROWN —
| GREEN / YELLOW ZT
2. For single-phase connection,connect as
identified below:
e
Brown cable = L (Phase)
e
Blue cable = N (Neutral)
|
e
Green/yellow cable = (E) == (Ground)
13/EN