WARNINGS FOR PRODUCT INSTALLATION
installation or repairing. Failure to do so can cause electric shock.
Installation must be performed by an authorized dealer or specialist. Defective
installation can cause water leakage, electrical shock, or re.
Installation must be performed according to the installation instructions.
Improper installation can cause water leakage, electrical shock, or re.
Contact an authorized service technician for repair or maintenance of this unit.
This appliance shall be installed in accordance with national wiring regulations.
Only use the included accessories, parts, and speci ed parts for installation.
Using non-standard parts can cause water leakage, electrical shock, re, and can
cause the unit to fail.
Install the unit in a rm location that can support the unit's weight. If the chosen
location cannot support the unit's weight, or the installation is not done properly,
the unit may drop and cause serious injury and damage.
Install drainage piping according to the instructions in this manual. Improper
drainage may cause water damage to your home and property.
For units that have an auxiliary electric heater, do not install the unit within 1
meter (3 feet) of any combustible materials.
For the units that have a wireless network function, the USB device access,
Do not install the unit in a location that may be exposed to combustible gas leaks.
If combustible gas accumulates around the unit, it may cause re.
Do not turn on the power until all work has been completed.
When moving or relocating the air conditioner, consult experienced service
technicians for disconnection and reinstallation of the unit.
How to install the appliance to its support, please read the information for details
in "indoor unit installation" and "outdoor unit installation" sections.
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner's circuit board (PCB) is designed with a fuse to provide
overcurrent protection. The speci cations of the fuse are printed on the circuit board,
for example: T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC,
T20A/250VAC, T30A/250VAC, etc.
NOTE: Only the blast-proof ceramic fuse can be used.
WARNING FOR USING FLAMMABLE REFRIGERANTS
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open ames, an operating gas appliance or an operating
electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
For R454B refrigerant charge amount and minimum room area:
The machine you purchased may be one of the types in the table below. The indoor
and outdoor units are designed to be used together. Please check the machine you
purchased. The indoor unit should be installed at least 8.3ft/2.5m above from the
oor, the height of the room cannot be less than the indoor unit installed height,
and the minimum room area of operating or storage should be as speci ed in the
following table: