Télécharger Imprimer la page

Chamberlain LiftMastar PROFESSIONAL SLY300/E/K Manuel D'installation page 10

Publicité

INITIAL OPERATION
Check gate functionality manually when the drive has been
disengaged. Electrical operation is only possible with the control unit
that is supplied as standard.
Electrical connections: See control unit instructions.
Always ensure that the mechanical and electrical safety requirements
relevant to the given system are complied with. fig. 10
MAINTENANCE WORK
The drive mechanics are maintenance-free. Check at regular
intervals (monthly) that the gate hardware and the drive are all firmly
in place. Disengage the drive and check gate functionality. Only an
easy-running gate will work well with a drive. A drive is no substitute
for a poorly functioning gate.
A sliding gate can also be secured by implementing on-site
measures (fence, wall, etc.). See fig. 11.
709269E-GB - 11.2005
All manuals and user guides at all-guides.com
D e c l a r a t i o n o f C o n f o r m i t y
Automatic Gate Opener Models SLY300/E/K, SLY500/E/K, SLY1000/E/K Series
are in conformity to the applicable
sections of StandardsEN300220-3 • EN55014 • EN61000-3 • EN60555, EN60335-1 • ETS
300 683 • EN60335-1: 2002 • EN60335-2-103: 2003 • EN55014-1: 2000 + A1 + A2 •
EN55014-2: 2001 • EN61000-3-2: 2000 • EN61000-3-3: 1995 + A1 • EN 301 489-3,
V1.3.1 • EN 300 220-3 V1.1.1 • EN13241-1
per the provisions & all amendments
of the EU Directives ..................................................73/23/EEC, 89/336EEC, 1999/5/EG
D e c l a r a t i o n o f I n c o r p o r a t i o n
Automatic Gate Opener Models , when installed and maintained according to all the
Manufacturer's instructions in combination with a Gate, which has also been installed and
maintained according to all the Manufacturer's instructions, meets the provisions of EU
Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
B.P.Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
October, 2005
© Chamberlain GmbH 2005
TECHNICAL DATA
SLY300
Voltage IN
230Volt
Frequency
50Hz
Power
300W
Current rated
1.3A
Torque
9Nm
Capacitor
8μF
Therminal Overload
Protection
140°
Motor Speed
1400
Travel Speed
12
Duty Cycle
30
Working Temperatur
Range
-20
Protection Class
IP44
Degree of Protection
I
Weight
9
approx. Gate Length
5m
Max. Gate weight at
max. length (incl.
20% reserve)
300kg
conforms to the above Directives and Standard
SLY500
SLY1000
230Volt
230Volt
50Hz
50Hz
480W
360W
1.5A
2.1A
10Nm
12Nm
10μF
16μF
140°
140°
1400
1400
12
11.5
30
30
O
C - 55
O
C
-20
O
C - 55
O
C
-20
IP44
IP44
I
I
9
10
8m
10m
500kg
1000kg
s.
O
C - 55
O
C

Publicité

loading