3
Illustration
1 Tool holder
2 Dust protection cap
3 Unlocking collar
4 Drilling/Impact drilling selector
5 Ventilation slots
6 ON/OFF switch
7 Rotational direction switch
8 Unlocking button
9 Battery
10 Auxiliary handle
11 Depth stop
12 Battery charging unit
13 LED charging condition indicator
14 Battery charging cavity
Accessories illustrated or described are not always
included as standard delivery items.
4
Technical Data
Battery-Powered
Pneumatic Drill Hammer
Article number
Input power
Output power
No-load speed
Speed under load
Load hammer blows
Impact energie
Right/Left rotation
Clamping collar dia.
Tool holder
Drill dia.:
- Steel
- Light metal
- Wood
Hammer drilling in conctrete
Recommended hammer drilling
range
Screw dia.:
- Wood
- Sheet metal
Corner measure
Weight
Battery
Type
Rated voltage
Capacity (NiCd/NiMH)
Number of cells
Operating temperature range
Weight
Battery charging unit
Input voltage
Output voltage
Charging current/time
Weight
5
Measured values determined according to
EN 50 260.
Sound pressure level:
Sound power level:
Work place emission value:
For operation, noise protection measures are
APH 240
required.
The acceleration measured is usually less
360 W
than 12 m/s
275 W
-1
0-1000 min
6
-1
0-800 min
max. 4400/min
Mounting the Auxiliary Handle
max. 2.0 J
Only use the machine together with the auxiliary han-
•
dle 10. Place the auxiliary handle onto the clamping
43 mm
collar and tighten firmly with the handle piece.
Euro standard
SDS-Plus
7
The rated voltage of the battery must agree with the
max. 10 mm
value on the machine.
max. 13 mm
– The batteries are not charged. They therefore have
max. 20 mm
to be charged before use.
max. 20 mm
– A new battery develops full power only after it has
been subjected to approx. 5 charging and dis-
4-14 mm
charging cycles.
– The maximum service life of the batteries is
max. 6 mm
attained if you charge these at an ambient temper-
max. 6.3 mm
ature of between +5 °C and max. +45 °C.
33 mm
– If the battery is not within the permitted loading
3.6 kg
temperature range (approx. +5 °C and +45 °C)
charging time is extended by the cooling or warm-
up time.
Noise/vibration information
2
.
Auxiliary Handle
Charging the batteries
APH 240
AP 240
NiCd
24 V
1.2 Ah
20
+5 °C ... +45 °C
1.2 kg
CLG 120
230 V ~
24 V
max. 0.75 A/
max. 120 min.
approx. 1.65 kg
80 dB (A)
93 dB (A)
83 dB (A).