Napoleon WSX-N Serie Instructions D'installation Et D'opération page 43

Fournaise à gaz multiposition à air pulsé haute efficacité (condensation), à deux étapes

Publicité

42
FIGURE 29 - INTEGRATED FURNACE IGNITION CONTROL
IOM
IOM
TERMINALS
ELECTRONIC
AIR CLEANER
POWER
HUMIDIFIER
120 VAC
MOLEX
120 VAC NEUTRAL
CONNECTIONS
14.2
FURNACE CONNECTION
The furnace is shipped fully wired except for the connections to the house wiring. The furnace power
connections are made in a junction box inside the blower compartment. The junction box contains a BLACK
wire to be connected with L1 (hot), a WHITE wire to be connected with L2 (Neutral), and a GREEN wire to be
connected to the ground.
NOTE
Use good quality wire nuts such as Marrette®
connectors, Ideal® wire nuts, etc.
If the junction box must be moved from it's original location to the other side of the unit.
1. Remove the appropriate knockouts from opposite panel and fi ll holes not being used with caps supplied in
the furnace baggie.
2. Fasten the junction box to the selected panel.
3. Secure power line connection into junction box, following above reference.
4. Use only ground screws for junction enclosure.
THIS FURNACE IS EQUIPPED WITH A BLOWER DOOR SAFETY SWITCH. DO NOT
DISABLE THIS SWITCH. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN
W415-2379 / B / 09.22.20
PARK
ELECTRICAL SHOCK, PERSONAL INJURY, OR LOSS OF LIFE.
5A FUSE
HEAT STAGING
JUMPER P5
IMPORTANT:
USE COPPER CONDUCTORS ONLY.
WARNING
!
!
24 VAC MOLEX
ICM
INTERFACE
THERMOSTAT
TERMINALS
FAULT CODE
BUTTON
RED STATUS
LED
H19.4
H3.23