USING A CENTRAL CONTROL UNIT
To use the central control unit, your device must be in Manual mode.
The device follows the commands from the central control system for your installation via
a Pilot Wire connection. It will display the commands sent by your control unit. Use your
central control unit to perform the operations (follow the instructions in the manual for your
control unit).
Manual
7
.0
Prioritized order
Manual
1
9
.0
Prioritized load shedding
FP ECO
1
5
.5
FP
FP -1°C
1
8
.0
FP
FP -2°C
1
7
.0
The pilot wire must be connected. During reduction periods, the device will display the
commands sent by the pilot wire.
The temperature can be modified when the device is in MANUAL mode with an Eco,
-1 °C or -2 °C command. This temperature modification is maintained until the command is
changed via the pilot wire.
The temporary temperature modification can be cancelled by pressing the Back button.
The control unit sends a Frost-Free command:
the device maintains the temperature at 7 °C.
The control unit sends a load shedding command:
the device does not heat up.
The control unit sends an Eco command:
Eco
the temperature is reduced by -3.5 °C
The control unit sends a -1 °C command:
the temperature is reduced by 1 °C.
The control unit sends a -2 °C command:
the temperature is reduced by 2 °C.