Télécharger Imprimer la page

BEA LZR-H100 Mode D'emploi page 8

Masquer les pouces Voir aussi pour LZR-H100:

Publicité

2
FIELD POSITIONING
The detection field and reference position are very important for the good functioning of the barrier.
1
Activate the visible laser beams by remote control to position
the sensor correctly.
2
Use a white paper to verify the position of the 0° laser beam.
The reference point can be adjusted on any object at the end
of the boom or farther away. Its surface should be +/- 10 cm
and it must be firmly fixed.
Use the reflective sticker when the distance between sensor
and reference is higher than 5 m (see p. 4)
3
- The 0° spot must be parallel to the boom.
- The beginning of the opening field should be at midcalf height.
4
To finish, lock the sensor position by using a PH1 screwdriver.
8
+/- 30 cm
45°
90°
To turn them off, use the same sequence.
After 15 min. the beams switch off automatically.
Turn the sensor slightly on its axis to adjust
the lateral angle of the sensor to place the
0° laser spot on the reference.
Adjust the tilt angle of the detection
field witht the hex key if necessary.

Publicité