4
SAFETY FIELD
1
FIELD DIMENSIONS
Before launching a teach-in, the field dimensions can be adjusted by remote control.
Value C must be adapted to the width of the boom:
•
when the reference point is farther away than the desired detection field width
when a mounting side without reference has been selected
•
WIDTH
DEPTH
EX:
You can also increase or decrease the field by 10 cm:
2
TEACH-IN
Launch a teach-in by remote control. You have 3 seconds to step out of the detection field.
Then wait for the sensor to learn its environment (30 seconds).
During the teach-in, the detection field must be free of snow buildups, heavy rain, snowfall, fog or other moving
objects.
Once the sensor has finished the teach-in,
make sure that the safety field is correctly
configured and that the area around the
barrier or gate is safe.
Always launch a new teach-in after adjusting the field dimensions.
If the safety field is the only protection against contact with the boom, the safety field of the sensor must be
situated right under the boom. This is only possible when the sensor is positioned correctly and the reference has
been learned.
The safety field is necessary for the correct functioning of the installation. If the safety field is badly adjusted,
the manufacturer of the sensor cannot be held responsible for inappropriate functioning of the installation.
Always verify the correct functioning of the safety field before leaving the premisses.
10
auto-set to
reference*
* without reference, the width will be automatically set to 9.9 m
for a field depth of 1.5 m
MIN
MAX
-
0.5 m
9.9 m
-
0.5 m
9.9 m
30 s
2.0 m