5
OPENING FIELD
1
FIELD DIMENSIONS
Before launching a teach-in, the field dimensions can be adjusted by remote control.
WIDTH
DEPTH
EX:
You can also increase or decrease the field by 10 cm:
2
TEACH-IN
Launch a teach-in by remote control. You have 3 seconds to step out of the detection field.
Then wait for the sensor to learn its environment (45 seconds).
During the teach-in, the detection field must be free of snow buildups, heavy rain, snowfall, fog or other moving
objects.
If the 1st red LED stays ON and no moving
objects are in the detection field, reduce the
opening field size or launch a new teach-in.
Always launch a new teach-in after adjusting the field dimensions.
same width as
safety field
if no opening
field is
needed
for a field depth of 5 m
MAX
MIN
-
0.5 m
9.9 m
-
0.5 m
9.9 m
45 s