SAFETY
CAUTION!
Use of controls, adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure.
Do not look into the
visible red laser beams.
This sensor is designed to be used as a movement and presence sensor to control the opening and the closing process of a
gate or a portal. The manufacturer of the system is responsible for installing the sensor and the system in compliance with
applicable national and international regulations and standards on safety. The manufacturer of the sensor cannot be held
responsible for incorrect installations or inappropriate adjustments of the sensor.
INSTALLATION & MAINTENANCE
The presence of fog or smoke can cause the sensor to switch to detection to maintain the system's safety. This
detection can therefore have consequences on the operation and availability of the system.
Make sure that such occasional behaviour is compatible with your installation/application.
Avoid extreme
vibrations.
Avoid exposure to
sudden and extreme
temperature changes.
2
The warranty is void if
unauthorized repairs are
made or attempted by
unauthorized personnel.
Do not cover
the laser windows.
Avoid direct exposure
to high pressure
cleaning.
The device emits invisible IR and visible laser radiations.
IR laser: wavelength 905nm; output power 0.10mW
(Class 1 according to IEC 60825-1)
Visible laser: wavelength 635nm; output power 0.95mW
(Class 2 according to IEC 60825-1)
The visible laser beams are inactive during normal functioning. The
installer can activate the visible lasers if needed.
Do not stare into the visible red laser beams.
Only trained and qualified
personnel may install and
adjust the sensor.
Avoid moving objects
and light sources
in front of the laser
window.
Do not use aggressive
products to clean
the laser windows.
After installation, enter
an access code by remote
control.
Avoid the presence
of smoke and fog in
the detection field.
Clean the laser window
with compressed air.
If needed, wipe only
with a soft, clean and
damp microfibre cloth.
Avoid condensation on
the laser windows.
Keep the sensor
permanently powered
in environments where
the temperature can
descend below 0°C.