3.4. Specifications
Technical data
General
Sound level ISO 11202
Dimensions HxWxD
Weight
IP class
Water
Max. outlet pressure
Operational flow range
Min. supply pressure
Max. supply pressure
Min. water supply
Max. water temperature
Pipe dimension inlet Ø
Pipe dimension outlet Ø
Connection type
Electricity
Supply voltage
Frequency
Motor load
Max. total load
Nominal current
Fuse
Electrical cable; L1 L2, L3, PE (min)
Output ratings:
Max. load single output
Max. load sum of all outputs
Voltage nom.
Voltage min.
Voltage max.
Input ratings:
Input voltage on
Min. input voltage on
Max. input voltage on
Max. input voltage off
Units
BF16
dB
<85
mm
1100x554x1006
[43.3x21.8x39.6]
["]
kg
190
[lbs]
[419]
55
MPa
(bar)
[psi]
L/min
10-440
[gal/min]
[2.6-116.2]
MPa
0.2
(bar)
(2)
[psi]
[29]
MPa
0.8
(bar)
(8)
[psi]
[116]
L/min
500
[gal/min]
[132]
70
[°F]
[158]
mm
88.9mm
["]
[3]
mm
88,9mm
["]
[3]
3" EN 1092-1 Type
11/B1 8 Bolts
V
3/PE 380-528 Vac
Hz
50/60
kW
22
kW
22.5
A
55
A
63
mm
4x16
2
A
A
V
V
V
V
V
V
V
BF24
<85
1100x554x1432
1100x588x1985
[43.3x21.8x56.4]
[43.3x23.1x78.1]
300
[661]
55
2+inlet max 2.5
(20+inlet max. 25)
[290+inlet max. 362]
10-660
10-880
[2.6-232]
[2.6-174.4]
0.2
(2)
[29]
0.8
(8)
[116]
750
[198]
70
[158]
88.9mm
[3]
88,9mm
[3]
3" EN 1092-1 Type
4" EN 1092-1 Type
11/B1 8 Bolts
11/B1 8 Bolts
3/PE 380-528 Vac
3/PE 380-528 Vac
50/60
33
33.5
82.5
100
4x35
0.8
2
24
22
24.5
24
22
25
2
BF32
<85
400
[882]
55
0.2
(2)
[29
0.8
(8)
[116]
1000
[264]
70
[158]
114
[4]
114
[4]
50/60
44
44.5
110
125
4x50
33

Publicité

loading

Ce manuel est également adapté pour:

Bf24Bf32