Circuit resistance calibration
705
Allows the calibration of the system.
Refer to section "Circuit resistance calibration (set up 705)".
Current reading
751
Allow the real value of the welding current to be displayed.
Voltage reading
752
Allows the real value of the welding voltage to be displayed.
HI heat input measurement
768
Allows reading of the value of the measurement of the heat input in welding.
EN 1011-1
5.1.2 List of set up parameters (TIG)
Save and Exit
0
Allows you to save the changes and exit the set up.
Reset
1
Allows you to reset all the parameters to the default values.
Pre-gas
2
Allows you to set and adjust the gas flow prior to striking of the arc.
Permits filling of the torch with gas and preparation of the environment for welding.
Minimum
0/off
Initial current
3
Allows regulation of the weld starting current.
Minimum
1%
Initial current time
5
Minimum
0/off
Slope-up
6
Allows you to set a gradual passage between the initial current and the welding current.
Minimum
0/off
Welding current
7
Allows the regulation of the welding current.
Minimum
3 A
Maximum
Default
99.9 s
0.1 s
Maximum
Default
200%
50%
Maximum
Default
99.9 s
0/off
Maximum
Default
99.9 s
0/off
Maximum
Default
Imax
100 A
Minimum
Maximum
3 A
Imax
23
SETUP
EN
Default
-