2-wheels and 2-props radiator
We thank you for choosing oil-filled radiator produced by TESY ltd. This is a
product that provides heating in cold winter weather according to customers'
needs for the achievement of comfortable temperature conditions in the
premises. If correctly maintained according to the terms of this manual the
appliance will provide long-life service.
OPERATION
Turning-on
P
ut the plug into the socket, turn thermostat knob clockwise and turn the
appliance on as follows:
Only button (I) is turned-on– light heating – MIN (W);
Only button (II) is turned-on – medium heating – MED (W);
Both buttons are turned-on – intense heating – MAX (W);
Power values of the corresponding levels (MIN(W), MED(W), MAX(W)) are
shown in table.
Model
MAX(W)
1005
1000 W
1006
1000 W
1506
1500 W
1507
1500 W
1508
1500 W
1509
1500 W
2008
2000 W
2009
2000 W
2010
2000 W
2011
2000 W
2012
2000 W
2510
2500 W
2511
2500 W
2512
2500 W
2513
2500 W
2514
2500 W
3012
3000 W
3013
3000 W
3014
3000 W
To turn off the appliance turn off the two buttons and take the plug out of
the socket outlet.
Concerning ONLY oil-filled radiators with an in-built overturn
protection switch (activates in case the appliance falls on the floor)
The radiator has an in-built overturn protection switch. In case of overturning it
will switch off the power supply to the appliance. After this kind of switch-off, let
the radiator cool down before setting it in upright position. Then it will restore
its normal operation.
NOT ALL oil-filled radiators are equipped with this function. You should check if
your appliance has this function – by tilting the radiator sideways the indicator
lights should switch off; by restoring the appliance back into upright position
they should switch on. DO NOT do this test when the radiator is hot – there is a
risk of burning.
Thermoregulator adjustment
Power switch and thermoregulator should be set to maximum position until
the desired room temperature is reached. Then turn thermoregulator switch
in the opposite direction till red light indicator goes down. Thermoregulator
may stay in that position after that. Immediately after room temperature falls
below thermoregulator value thermal switches are turned on automatically
until set temperature is reached. In that way room temperature is steady
with minimum energy consumption.
If you want to prevent temperature fall in the room below 0 degrees
Centigrade adjust thermostat switch in its initial position and turn on the
English
MED(W)
MIN(W)
600 W
400 W
600 W
400 W
900 W
600 W
900 W
600 W
900 W
600 W
900 W
600 W
1200 W
800 W
1200 W
800 W
1200 W
800 W
1200 W
800 W
1200 W
800 W
1500 W
1000 W
1500 W
1000 W
1500 W
1000 W
1500 W
1000 W
1500 W
1000 W
1800 W
1200 W
1800 W
1200 W
1800 W
1200 W
two power buttons.
24-hours timer models ("T")
Adjust the heating period in the following consequence:
Set the clock to the correct time. If it is 10 o'clock turn the figures dial
so that the mark is positioned to the figure of 10.
Note: Turn the figures dial only in the direction indicated with arrows! Adjust the
period of operation of the appliance by pushing black keys to the center – every
one of them corresponds to 15 minutes period. Sector of the pushed keys will correspond
to the period of operation of the radiator in automatic mode every day.
Important : Plug should always be connected to the socket outlet!
In order to change programmable period of automatic operation turn
black keys backwards and adjust new periods of operation.
If you do not want the appliance to operate in programmable mode
push all black keys to the center of the figures dial. To turn off the
radiator in that case you have to pull the plug out of the socket. In that
way unnecessary operation of the timer is avoided.
Thermal fan models ("V")
Models equipped with a 500W thermal fan offer faster achievement of
desired temperature and better ventilation in the room. Thermal fan
may function separately or together with oil-filled radiator. Thermal fan
is positioned in the bottom part of the front panel of the radiator and is
turned on by a switch positioned in that part of the panel. Cold air is
sucked through the grating in the front part of the front panel and hot air is
released in the room through the grating positioned in the bottom side part
of the radiator panel. Desired room temperature with thermal fan operation
is adjusted by thermoregulator of the radiator in the above mentioned
manner. For the normal operation of the thermal fan it is necessary that air
passes unobstructedly through inlet and outlet grating. Electrical device
is intended for domestic use in premises with low level of dust pollution.
Dust is accumulated after certain period of operation. In is necessary to
check periodically level of pollution and if needed to consult the service
organization for cleaning.
Note: In case of obstruction of grating of incoming and outgoing air thermal
protection is enabled. It turns off heater of the thermal fan. In that case disconnect
radiator from the socket outlet, eliminate the cause of the obstruction, wait about
5 minutes and turn on the radiator again. If the thermal fan does not operate connect
authorized service at your location.
Minimum distance between hot air outlet of the thermal fan and furniture (or
other objects) should be 60 cm.
We recommend when desired room temperature is achieved to turn off thermal
fan and to operate the appliance only in "radiator mode".
ON/OFF
MAINTENANCE
In order to provide long period of operation your oil-filled radiator does
not need any kind of special maintenance. Clean radiator with a damp soft
cloth. Do not use solvents or abrasive detergents. If necessary use a vacuum
cleaner to clean the dust from the radiator!
Instructions for environmental protection
Obsolete electric devices contain valuable materials and therefore
they should not be treated as domestic waste! We ask you for
cooperation with your active behavior for the protection of
resources and nature. We ask you to return your appliance at the
organized buy-back stations (if there are any).