Possible voltage options
208/240 V 60 Hz 2 Ph
Power source
Total amps
Maximum fuse rating (time-delay fuse)
Minimum current
Supplied power cable
Supply air
Recommended free air intake cross-section into the room:
(equivalent to 3 times the exhaust air cross-section of a machine).
There must be sufficient air intake to the installation site to match the air outlet volume.
Exhaust air
Maximum nominal volume flow rate
Maximum permitted pressure loss
Connector on machine side (external diameter)
Connection pipe provided on site (internal diameter)
Maximum exhaust air temperature
As relative humidity inside the exhaust ducting can be as high as 100%, suitable measures must be taken to prevent a backflow of con-
densate into the machine.
Equipotential bonding
Connection with male thread
Washers and nuts
Equipotential bonding with good contact connection must be provided in accordance with all national regulations. Accessories for
equipotential bonding are not supplied and need to be ordered separately.
Machine data
Machine width, total
Machine height, total
Machine depth, total
Niche width
Minimum wall spacing (up to the back edge of the lid)
Packaging width
Packaging height
Packaging depth
Maximum gross volume
Maximum gross weight
Maximum net weight
Max. floor load in operation
Diameter of exhaust duct
Drum diameter
Diameter of drum opening
Drum depth
Drum volume
en - Technical data
208/240 V
3 x AWG10 with NEMA L6-30P plug
320 m³/h
4" (100 mm)
4" (100 mm)
176°F (80°C)
10 x 35 mm
27 9/16" (700 mm)
40 3/16" (1,020 mm)
30 1/16" (763 mm)
32 5/16" (820 mm)
15 3/4" (400 mm)
29 15/16" (760 mm)
47 13/16" (1,215 mm)
32 5/16" (820 mm)
176 lb (80 kg)
159 lb (72 kg)
4" (100 mm)
25 9/16" (649 mm)
17 13/16" (452 mm)
21 5/8" (550 mm)
60 Hz
2 Ph
21.9 A
30 A
21.9 A
339 cm²
420 Pa
M10
757.2 L
853 N
180 L