Voltage error.
Battery voltage too low. (You are
attempting to charge a 6 V battery).
Er04
One or more elements of the battery
has/have short-circuited.
Battery voltage too high compared
Er05
to that set. (You are attempting to
charge a 24 V battery).
Battery capacity excessive. Unable
Er06
to reach end condition.
The clamps of the output leads
Er07
and LED
are not connected correctly to the
«
Reverse
»
battery.
Excessively high output current.
Er08
Current exceeds maximum limit.
5. OPERATING BATTERY CHARGER
1. Before starting to charge the battery, make sure that the power supply lead is not
plugged into the mains supply!
Charging batteries connected to motor vehicle
2. Locate the motor vehicle's earthing point, which is normally connected to the negative
battery terminal.
3. Charge a battery with negative earth, grounded to the motor vehicle's chassis, as
follows:
• Connect the output lead with the red clamp to the positive terminal (+) of the battery.
• Connect the output lead with the black clamp to the motor vehicle's earthing point,
keeping it away from the battery and fuel pipe.
Charge a battery with positive earth, grounded to the motor vehicle's chassis, as follows:
• Connect the output lead with the black clamp to the negative terminal (-) of the battery.
• Connect the output lead with the red clamp to the motor vehicle's earthing point, keeping
it away from the battery and fuel pipe.
Connecting batteries that are not connected to a motor vehicle
2. Connect the output lead with the red clamp to the positive terminal (+) of the battery.
3. Connect the output lead with the black clamp to the negative terminal (-) of the
battery.
ATTENTION: Make sure that both clamps of the output leads generate a suitable contact with
their corresponding terminals.
4. Once the output leads have been connected to the battery, plug the power supply lead
of the battery charger into the mains socket, making sure that the voltage matches the
rated voltage of the battery charger; having done this, the battery charger will emit an
acoustic signal for 0.5 seconds, and all the LED indicators on the control panel will switch
on for 2 seconds; at this stage, the display shows
5. The battery charger is configured in stand-by mode: for example «
LED on, «
Charge
saved.
6. At this stage, with the battery charger in stand-by mode, set the charging parameters
»
5-50 Ah
LED on. The LEDs light up differently based on the last program
Set a «
Recovery
battery charger with supported 12 V
batteries.
Start charging the battery again.
The battery may be defective.
Only use the battery charger with
supported 12 V batteries. Start
charging the battery again.
Use a battery charger with greater
capacity.
Position the clamps correctly and
start charging the battery again.
Reduce battery absorption.
"- - -
-".
- 7 -
» cycle. Only use the
ON
» LED on, «
Wet
EN
»