Commissioning; Troubleshooting; Appliance Handover - Stiebel Eltron CWM 500 P Utilisation Et Installation

Masquer les pouces Voir aussi pour CWM 500 P:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
iNSTallaTiON

Commissioning

10.6.2 CWM U series
The appliance is delivered with a power cable without a plug.
f When wiring the appliance in permanently, connect the
4-core cable to a connection socket as illustrated:
1 Neutral conductor = blue
2 Live = brown
3 Earth conductor = green/yellow
4 Control cable = black
There are 3 possible ways to connect the appliance:
- Appliance connection without control cable
Unregulated appliance. The control cable is not connected. In this
case, insulate the control cable.
- Temperature setback via control cable
To reduce the temperature to the set setback temperature, the
black control cable is activated via an external electronic contact
(e.g. a time switch).
- Control cable connected to external control unit
The appliance can be connected to any control unit that issues the
following waveforms as control signals.
instruction
Oscilloscope
No electrical
power
Complete oscil-
lation 230 V
Semi-oscillation
negative -115 V
Semi-oscillation
positive +115 V
Full oscillation
230 V for 3 sec-
onds
Full oscillation
230 V for 7 sec-
onds
www.stiebel-eltron.com
1
1
2
2
3
3
4
4
Operating
Heating temper-
mode
ature
Comfort mode Subject to set comfort
temperature
Setback mode Subject to set setback
temperature
Frost protection Frost protection tem-
perature
Stop
None
Comfort mode
1 °C less than the set
-1 °C
comfort temperature
Comfort mode
2 °C less than the set
-2 °C
comfort temperature
11. Commissioning
The appliance is ready for operation as soon as it has been fixed
to the installation wall and plugged into the mains.
f Remove the protective film from the programming unit.

12. Troubleshooting

The power cable must only be replaced (for example if damaged)
by a qualified contractor authorised by the manufacturer, using
an original spare part.

13. Appliance handover

Explain the functions of the appliance to the user. Draw special
attention to the safety instructions. Hand over the operating and
installation instructions to the user.
CWM P | CWM U |
11

Publicité

Table des Matières
loading

Table des Matières