INsTALLATIoN
Commissioning
≥183
f Unhook the wall mounting bracket from the appliance.
f
f Place the centred wall mounting bracket horizontally on the
f
floor. Mark holes 1 and 2.
f Lift up the wall mounting bracket so that its lower holes
f
match up with the markings you have just made on the in-
stallation wall.
f Mark holes 3 and 4 on the installation wall.
f
f Drill the holes at the 4 markings.
f
f Secure the wall mounting bracket with suitable fixing ma-
f
terials (screws, rawl plugs). With the vertical slots, you can
compensate for an offset fixing hole.
10.3 Appliance installation
1 Wall mounting bracket
f Hook the appliance onto the bottom tabs of the wall mount-
f
ing bracket by the slots in the back of the appliance.
f Place the appliance in an upright position.
f
f Secure the appliance by pushing it towards the wall until it
f
audibly snaps into place in the two upper springs on the wall
mounting bracket.
1
1 Appliance
2 Locking screw
f Secure the appliance against unintentional release using the
f
supplied locking screw on the right or left-hand side of the
wall mounting bracket.
www.stiebel-eltron.com
≥183
1
2
10.4 Removing the appliance
f Undo and remove the locking screw from the wall mounting
f
bracket.
f To release the appliance, push down the springs at the top of
f
the wall mounting bracket.
f Tilt the appliance away from the wall and lift it off the bottom
f
tabs on the wall mounting bracket.
10.5 Electrical connection
WARNING Electrocution
- Carry out all electrical connection and installation
work in accordance with relevant regulations.
- Do not install the appliance with a fixed power
cable.
Material losses
- Observe the type plate. The specified voltage must
match the mains voltage.
- Ensure the on-site supply cable has an adequate
cross-section.
The appliance is supplied fully wired (with a mains plug), but it is
also suitable for permanent connection.
10.5.1 Connection to a standard socket
f Plug the appliance into a standard socket.
f
10.5.2 Permanent connection to an appliance junction box
WARNING Electrocution
In the case of a permanent connection, the appliance
must be able to be separated from the power supply by
an isolator that disconnects all poles with at least 3 mm
contact separation.
Material losses
- Trim the power cable so it leads directly to the appli-
ance connection socket.
- Ensure that, after trimming the power cable, the
appliance can still be removed from the wall without
a problem.
f Trim the power cable by cutting off the plug.
f
f Connect the power cable to a suitable appliance junction box.
f
11. Commissioning
The appliance is ready for operation as soon as it has been fixed
to the installation wall and connected to the mains.
f Remove the protective film from the programming unit.
f
12. Troubleshooting
The power cable must only be replaced (for example if damaged)
by a qualified contractor authorised by the manufacturer, using
an original spare part.
CK 20 Premium |
23