FAULTS
Fault
The burner does not burn
evenly.
The burner goes out after
igniting.
Fault code 'b'.
Fault code 'Flt06'.
Fault code 'Flt09'.
Other fault codes.
EN 16
Possible cause
Burner parts incorrectly
installed.
Burner parts dirty or damp.
Wrong type of gas used.
Control knob not kept
pressed in long enough.
A single burner is locked.
Upper limit of 5 releases in
15 minutes exceeded.
Electronic error.
Solution
Assemble the burner parts
using the centring ridges.
Clean and dry the burner
parts, making sure that the
outflow holes are open.
Check that the gas used is
suitable for the appliance. If
not, contact your gas fitter.
Keep the control knob
pressed in for at least
5 seconds.
Release the burner, see
page 9.
The device will accept no
further request for release for
another 15 minutes.
Release the burner, see
page 10. Contact the service
department.
Contact the service
department.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gk575Gk595Gkt564Gkt595

Table des Matières