An even installation place has to be provided. The foundations must be based
in a frost resistance depth, both outside and indoors, where you must reckon
with frost.
• A standard electrical supply 3~/N+PE, 400 V, 50 Hz must be provided. The supply
line must be protected with T16A (VDE0100 German regulation). The minimum
diameter amounts to 2.5 mm². (Pay attention to the tension of your state)
• The air plug requires an air hose with diameter 0.24 inch, the operation pressure
needs to be 6 to 10 bar.
• All cable ducts have to be equipped with protective coverings to prevent
accidents.
9.2 Erection and doweling of the lift
• Erect power unit, plug air – and electricity connections
• Fill oil tank with oil: viscosity 32 cst, hold-up: approx. 10 litre
• connect hydraulic and pneumatic hoses and electrical cable between power
unit and automotive lift
• Push button "lift" at automotive lift until command side is lifted up high enough
to touch the ventilation screw. If this does not work, press override switch
additionally until the lift reaches the appropriate height.
• Open ventilation screw at command cylinder until oil leaks (Do not unscrew!)
• Close ventilation screw immediately and tighten.
• If the automotive lift needs to snap into ratchet before oil leaks from the
ventilation screw, the ventilation screw needs to be closed and the lift needs to
be lifted once more marginally by pushing the button "lift". After that repeat
procedure described earlier, until oil leaks.
• Perform balancing of rails as described in chapter 5.3.
• Lift up automotive lift to 60 inch.
• re-check placement of the first and second base plate
• Dowel power unit in floor.
• Setting of the lift, first each rail separately, then both rails together.
Asynchronism needs to be fixed by laying boards underneath the bearing.
• tighten Liebig-dowels with torque wrench (observe the regulation of the dowel
manufacturer)
• Lift up and lower automotive lift, loaded with vehicle, several times, retighten
dowels and check hydraulic hoses for closeness.
• Bore holes to fix the dowels through the borings of the base plates. Clean holes
with pressure air. Put in safety dowels with washers in borings. The manufacturer
remommends LIEBIG safety dowels type or equal dowels of another
manufacturer but pay attention to their regulation.
UNI LIFT 6500 - 8000
Operating instruction and documentation
- 55 -
UNI-LIFT 6500 - 8000
Version 4.2