Warning lamp:
Ramp is uneven.
Photocell is
interrupted.
on the side:
Bridging button, to
bypass the
photocell
5.2 Lowering the vehicle
•
Check the dangerous places of the lift and be sure that there are no objects
or people in the immediate area of the lift or on the lift.
Lower the vehicle to the working height or until the platform reaches the
•
lowest point; press the button „lowering"
Attention!
Shortly before reaching the lowest position, the lift stops the lowering process
for safety reasons (CE-STOP). Before the button"(lowering" is pressed again,
the working area of the lift must be checked again. No person or objects are
allowed in the endangered area of the lift.
•
Press the "lowering" button again, to lower to the lowest position. An acoustic
warning signal will sound during lowering.
5.3 Equalization of the platforms
If the difference in heights is constantly present, proceed as follows:
Equalize the rails only without load.
Remove any kind of load from the lift, before starting an equalization.
• Push the bridging button on the side of the power unit.
The bridging switch may only be pressed to restore the normal operating
state of the lift! Do not use the bridging switch during normal operating mode.
UNI LIFT 6500 - 8000
Operating instruction and documentation
.
- 44 -
UNI-LIFT 6500 - 8000
Version 4.2