The supports must be removed before lowering the lift to the ground.
Otherwise the lift can be seriously damaged.
• Continue lowering the lift (loosen set screw again) until the lift has reached its
lowest position.
• Fasten set screw and secure it by fastening the security screw.
• Turn out thread pins at both stop valves at cylinder bottom of hydraulic
cylinders. Secure them with the red security nuts.
After finishing the emergency lowering, all of the set screws must be brought
into the position they have had before. Otherwise a malfunction of the lift
can occur.
• Reinstall covering plates of both stop valves in the drive-on areas of the drive-
on rails.
• Drive off vehicle from the lift
• Shut down the lift until the defective pieces or valves have been replaced
UNI LIFT 6500 - 8000
Operating instruction and documentation
picture 4
picture 5.
- 49 -
UNI-LIFT 6500 - 8000
Valve with
central
emergency
lowering
Version 4.2