Charging Light Sequence
Signal (LED)
Orange LED on
Green LED on
NOTE: Re-charge the machine fully after its last use. Do not leave the machine in a discharged state.
Under abnormal use;
i.e. leaving the machine without charging for a period of time, we advise that you
follow these steps:
If the machine will be standing unused for a period of 30 days or more, then batteries
must be fully charged and battery fuses removed using the maxi fuse-puller provided,
prior to this period.
Batteries should be re-charged every three
months.
Charge fully the day before you start using the
machine again.
Free Wheel Function
1
The machine is equipped with a free-wheel function that will enable the operator to move the machine manually if required.
The motor brake is located on the right side of the machine near the rear wheel.
Pull the arm out (Fig.1). Swing to the disengaged position (Fig.2).
The motor brake will be fully disengaged. The machine will now be in full free wheel mode.
!
ALWAYS ENSURE THAT THE MACHINE IS ON LEVEL GROUND BEFORE DISENGAGING BRAKE ARM.
NEVER DISENGAGE THE BRAKE WHEN THE MACHINE IS ON A SLOPE / GRADIENT.
Remember to re-engage the drive when you reach your final destination / before using the
Red LED on
First Phase (constant current Mode).
Second Phase (Constant Voltage Mode).
Third Phase (Constant Voltage Mode) Charge Complete.
Cooling Fan Locked > 1 flash between pause.
Over Voltage Protection / Output Short Circuit / Battery Reverse Polarity
Red LED
flashing
> 2 flashes between pause.
followed by
Pause
Over Temperature Protection > 3 flashes between pause.
Charge Time has exceeded 10 hrs during phase 1 or 2 > 4 flashes between pause.
Note: Drive functions on the machine will not work whilst in free-wheel mode.
Meaning
2
!
machine..
25
T 01460 68600