Brush Weight
Brush Sizes
13/28/50kg
2 x 370 mm
Brush Motor
Brush Speed
600W
150rpm
Transaxle
Water Flow
Power
0 - 3l/min
400W
Run
Recharge
Time
Time
5hr
8-10HRS
MAX
20A Charger
PROBLEM
Machine will not operate
Vacuum will not operate
Poor water pick-up
No brush / scrub function
Little or no water flow
Machine just 'stops' during
operating
Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or
Model - TGB 8572/200T
Brush Pressure
8.2/17.5/31.3
g/cm
Vac Motor
400W
Gradient
Drive Speed
Max 6%
0 - 4.2 kph
Battery
Dimensions
Weight
Width = 762 mm
12v/100Ah
Length = 1513 mm
- 31.8kg
Height = 1144 mm
CAUSE
Missing or blown fuses
Low battery charge
Machine is connected and charging
Waste tank full switch stuck or clogged
Key is off or missing
Handle safety fuse blown
Missing or blown fuse
Waste tank full switch stuck or clogged
Vacuum switch not engaged
Waste water tank full
Waste water tank full
Clogged / blocked vacuum hose
Loose hose connections
Debris basket filter clogged / blocked
Separator filter clogged / blocked
Poor separator seal
Damaged separator seal
Damaged / split vacuum hose
Damaged floor tool blades
Low battery charge
Floor tool incorrectly adjusted
No brushes fitted
Brush deck raised
Missing or blown fuses
Clean water tank empty
Clean water tank filter blocked / clogged
Water flow not on
Brush deck raised
Too much load on the brush system
Brush motor fuse blown due to high load
Handle safety fuse blown
Numatic Technical helpline +44 (0)1460 269268
Pad sizes
2 x 360 mm
2
Vac Motor Suction @
Squeegee
120 mbar
Gross
Weight
355kg
Squeegee
Width
≤70
948mm
Specifications
Pad Pressure
6.9/14.8/26.4
1250m
g/cm
2
Vac Motor Airflow @
Squeegee
24
l/sec
Nett Weight
Power Source
270kg
Gel Battery 24V (4 x 12V) 200Ah
Hand Arm
Noise
Vibration
dB(A)±
≤2.5m/s
2
3dB(A)
Trouble Shooting
SOLUTION
Fit or replace fuse (page 7)
Charge batteries (page 23 / 24)
Take off charge (page 23)
Inspect & clean switch inside tank (page 19)
Insert key & turn to operating position
Replace fuse (or contact service engineer)
Fit or replace fuse (page 7)
Inspect & clean switch inside tank (page 19)
Press switch
Empty waste water tank (page 19)
Empty waste water tank (page 19)
Remove and clean (page 19)
Push tight connections (page 11)
Remove and clean (page 19)
Remove and clean (Page 19)
Clean and refit (page 19)
Renew (contact service dept)
Renew (contact service dept)
Renew (contact service dept)
Re-charge batteries (page 23 / 24)
Adjust floor tool
Check and fit (page 9)
Lower brush deck (page 15)
Fit or replace fuse (page 7)
Fill clean water tank (page 11)
Remove and clean (19)
Switch on water flow (Page 15)
Lower brush deck (page 15)
Decrease the brush load to best suit the
floor type (page 17).
Replace fuse & reduce load (page 7)
Replace fuse (or contact service engineer)
T 01460 68600
Cleaning Area
/HOUR@2kph
2
Water Capacity
85L
Water Ingress
Protection
IPX4
27