Technical data
13. Technical data
NOTE: The data given on the rating plate
attached to the top of the luminaire apply.
13.1 Dimensions
Designation
Dimensions of
the luminaire
Distance
between sus-
pension points
for single lumi-
naire
Distance
between sus-
pension points
for luminaire for
daisy chaining
Height of lumi-
naire
Tab. 4: Dimensions.
13.2 Electrical values
Designation
Value
Voltage range
220-240 V AC
Frequency
50/60 Hz
range
Power con-
The power consump-
sumption
tion is specified on the
rating plate of the lumi-
naire.
Starting cur-
IPP 7000/840/D: 25 A
rent
IPP 7000/VTL/D: 50 A
(per luminaire)
t = 280 µs
Operating
Integrated in the lumi-
device
naire body
Tab. 5: Electrical values.
Value
1200 x 250 x 30 mm
1184 mm
Start luminaire:
1207 mm
Middle luminaire:
1230 mm
End luminaire:
1207 mm
300 – 700 mm
13.3 Weight
Designation
Luminaire
Tab. 6: Dimensions.
13.4 Classification
Designation
Protection class I
Degree of pro-
tection
Operating
mode
Technical safety
check
Tab. 7: Classification.
13.5 Symbols
Symbol
Designation
Caution, dangerous volt-
age!
Risk of the electric shock
Protection class I
Operation with protective
earth terminal
CE conformity mark
For indoor use only.
ENEC approval
Disposal in accordance
with the European WEEE
Directive
Tab. 8: Symbols.
ENG
Value
approx. 7 .5 kg
Value
IP 20
Continuous operation
EN 60598-1
37