Service & maintenance
Cleaning
The machine must be switched off and unplugged before cleaning and maintenance.
Filter replacement
The fine filter must be replaced at least once a year. Only original filters may be used. HEPA filters must be
replaced after 300 hours.
WARNING
Filter replacement may only be performed by trained personnel. Use a protective mask and
suitable equipment.
CAUTION
When replacing the filter, no tools/sharp objects can be used as these may damage the sealing
surface of the filter.
1.
Loosen and lift off the top part to gain free access to the filter.
2.
Put the included plastic bag over the cyclone to prevent the dust in the filter from spreading.
3.
Lift the filter straight up.
4.
Seal the plastic bag with the used filter.
DC Tromb Turbo
1. Remove lock pin
2. Remove lid
37