Operation
Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications.
Starter box:
1.
Start button
2.
Warning light
3.
Stop button
The warning light comes on in the event of a fault. For more detailed descriptions, refer to the Troubleshooting
chapter.
If the warning light comes on at startup, this is due to a phase fault. Change the phase direction of the connector on
the connection cable.
Overload protection. The machine is equipped with overheating protection. A thermal cutoff is located in the
machine, switchable at 100°C. In these situations, it is important to investigate the cause of the overheating. Turn
off and disconnect the power supply, and then wait for the machine to cool down (this can take up to 30 minutes).
Filter cleaning
The filters should be cleaned when the manometer is in the red field.
1.
Leave the machine switched on and close the damper on the cyclone inlet.
2.
Adjust the filter cleaning button.
3.
Wait for 5-10 pulses.
4.
Switch off the machine.
5.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
6.
Switch on the machine.
7.
Check that the pressure gauge is on green. If not - repeat the procedure. If the meter is on red even after the
repetition, the fine filter needs to be replaced.
DC Tromb Turbo
1
2
3
33