Télécharger Imprimer la page

GASLAND GH Serie Mode D'emploi page 15

Publicité

Table 2: How To Convert Gas Source
Adjustment of the reduced valve flow
Burners
Flame
Full flame
Regular
burners
Saving flame
Valve adjustment
Valve adjustment should be done with the control knob set at burner ON
saving flame position.
Remove the knob and shell, and adjust the flame with a tiny
screwdriver(see fig.7 below).
To check the adjusted flame: heat the burner at full open position for 10
minutes. Then turn the knob into the saving setting. The flame should not
extinguish nor move to the nozzle. If it extinguish or moves to the nozzle,
readjust the valves.
Flame selection
As the burners are adjusted correctly, the flame should be light blue, and
the inner flame should be clear. The size of flame depends on the
position of the related control knob.
Converting from LPG
to NG
Replace the burner
nozzle according to
the guidelines in table 1
Loosen the adjustment
spindle(see fig.7 below)
and adjust the flame
Fig. 7
Converting from NG
to LPG
Replace the burner
nozzle according to
the guidelines in table 1
Loosen the adjustment
spindle(see fig.7 below)
and adjust the flame
13

Publicité

loading