Table 1: Burners And Nozzle Speci cations
Adapting the gas cooktop for different types of gas
Burner
Auxiliary
Semi rapid
Rapid
Triple Ring
Supply pressures
At 15°C and 1013 mbar - dry gas
P.C.I NG
40.1MJ/m³
P.C.I LPG 93.1MJ/m³
After you have converted the gas cooktop to another gas type, make
sure you have placed a label containing that information on the
appliance.
12
NG
Normal Burner
Capacities(Btu/kWh)
2800/0.82
5000/1.46
6500/1.90
9500/2.78
12.5mbar
Replacement of burner nozzle: loosen the nozzle with
a dedicated wrench(Fig. 7). Fit the new nozzle accord-
ing to the required gas type(see table 1 for reference).
Normal Burner
Nozzle1/100
Capacities(Btu/kWh)
(in/mm)
2.9 in/75 mm
3.9 in/100mm
4.5 in/115 mm
5.1 in/130 mm
LPG
Nozzle1/100
2800/0.82
2 in/53 mm
5000/1.46
2.6 in/68 mm
6500/1.90
3.1 in/79 mm
9500/2.78
3.6 in/93 mm
25mbar
(in/mm)