8.1 Electrical supply circuit requirements
The cord supplied with the gas rangetops having an electric griddle requires a NEMA 5-20 receptacle. All other gas
appliances require a NEMA 5-15 receptacle.
Model
PCG305W
PCG366W
PCG364WD
PCG486WD
Before you plug in an electrical cord, be sure all controls
¡
are in the OFF position.
A neutral supply wire must be provided from the power
¡
source (breaker) because critical range components,
including the surface burner spark reignition modules,
require it to operate safely and properly.
All 120 volt models must be plugged into a mating 3-
¡
prong, grounding-type receptacle. The receptacle must
be connected to a properly dedicated grounded and
polarized electrical power supply rated at 120 VAC,
single phase, 60 Hz.
Observe all governing codes and ordinances when
¡
grounding. In the absence of these codes or ordinances
observe National Electrical Code ANSI/ NFPA 70
current issue, or the relevant Canadian Electrical Code,
CSA C22.1 latest edition.
Power cord and receptacle should protrude no more
¡
than 2" (51 mm) from the rear wall.
Plug styles may vary.
¡
Voltage
120 VAC
120 VAC
120 VAC
120 VAC
Dedicated circuit
15 Amps
15 Amps
20 Amps
20 Amps
9 Installation procedure
Installation procedure
Installation procedure
9.1 Installing the low backguard (purchased
separately)
Installation methods will vary upon need. Before you begin
read these instructions carefully. Observe all local codes
and ordinances.
WARNING
Fingers or hands could get pinched when installing the
backguard. Severe injury could result.
Use extreme caution and wear thick protective gloves to
avoid potential laceration to finger or hand while sliding
the backguard down onto the range.
WARNING
To reduce the risk of fire or injury to persons, check to
make sure all packaging has been removed from
accessory devices before use.
Depending on model, remove the 2 or 3 stainless star
1.
head screws in the front face of the included island trim.
Lift up to fully remove the island trim.
Installation procedure en-us
Phase
Single
Single
Single
Single