15 Technical data
15.1 General
Power supply............................ 2x AAA 1.5 V batteries
Measuring categories ............... CAT III 600 V
Current measurement............... max. 40 A (AC/DC)
Display...................................... 4000 counts (2 – 3 renewals/sec.)
Clamp opening range ............... width: max. 5.5 mm, height: max. 13 mm
Automatic shut-off..................... approx. 15 mins
Display type.............................. EBTN
Operating altitude ..................... max. 2000 m (above sea level)
Operating conditions................. 0 to +28 °C, ≤95 % RH (non-condensing)
Storage conditions.................... -10 to +50 °C, ≤80 % RH (non-condensing)
Dimensions (W x H x D) ........... 188 x 51 x 36 mm
Weight ...................................... approx. 173 g
15.2 Test leads and probes
Rated voltage ........................... CAT III 1000 V
Rated current............................ 10 A
Protection class ........................ II
64
>+28 to +40 °C, ≤75 % RH (non-condensing)
>+40 to +50 °C, ≤45 % RH (non-condensing)