User Interface
(Fig. 1, Fig. 2, Fig. 15)
The User Interface 10 provides the following
functions:
• Status Indicator 22
• Mode Button 23
• Single Actuation Indicator 24
• Bump Actuation Indicator 25
• Battery Low Indicator 26
• Regular Service Due Indicator 27
• Major Service Due Indicator 28
• Reset Button 29
Fig. 15
24
25
22
23
Status Indicator
The Status Indicator 22 shows the status of
the nailer. A green light indicates that the
nailer is ready for operation. In case the Sta-
tus Indicator 22 light color is not green, con-
sult the "Troubleshooting" on page 23. for
further information.
Mode Button
Use the Mode Button 23 to toggle between
single actuation or bump actuation discharge
modes. The selection will be indicated by
either the Single Actuation Indicator 24 or
Bump Actuation Indicator 25.
Battery Low Indicator
The Battery Low Indicator 26 will only illu-
minate once the battery has reached 20%
charge or below. A yellow Battery Low Indi-
cator 26 signifies that the battery is 1-20%
18
Operation
26
27
28
29
full. A red Battery Low Indicator 26 signifies
that the battery is 0-1% full.
Regular Service Due and Major
Service Due Indicators
The Regular Service Due Indicator 27 or the
Major Service Due Indicator 28 will illumi-
nate once the nailer has reached a certain
amount of discharges. It is recommended to
return the nailer, battery pack and charger to
a BOSCH service facility for inspection and/
or service.
Reset Button
The Reset Button 29 is used to reset the
nailer to a normal state after an abnormal
condition is corrected. To reset the nailer,
press and hold the Reset Button 29 for 3
seconds.
Consult the "Troubleshooting" on page
23. for further information on resetting
the nailer.