Protection against dirt / oil

A Truma gas filter must be installed in front of the gas pressure
regulation system inlet in order to reliably protect it against
dirt / oil. A set of operating and installation instructions is sup‑
plied with the gas filter.

Installation dimensions

~ 131
A
37,5
Figure 3 Dimensions in mm. Not shown to scale

DuoControl CS installation and connection

The DuoControl CS must be installed in such a way that the
high‑pressure hose connections are in the highest possible
location, which must be at least higher than the cylinder valve
level (broken line).
30
~ 231
~ 170
A
The high‑pressure hoses must slope downwards all the way
to the cylinder valve.
Figure 4
Installation above the cylinder valves makes it more diffi‑
cult for gas in the liquid phase to penetrate the gas press‑
ure regulation system, particularly while driving.
The DuoControl CS must always be installed in such a way that
the high‑pressure hose connections are arranged horizontally.
Figure 5
The DuoControl CS is connected to the high‑pressure line
via the M20 x 1.5 (G.13) male thread at the inlet side and
is connected to the gas pipe via an olive screw connection
(8 or 10 mm) on the outlet side.