Technical data

(determined in accordance with EN 16129:2013 or Truma test
conditions)
Type of gas
Liquid gas (propane / butane)
Admission pressure
0.6 – 16 bar
Output pressure
30 mbar or 50 mbar, depending on variant
Nominal changeover pressure (p
750 mbar
Regulator capacity
1.5 kg/h
Regulator inlet
Male thread M20 x 1.5 (G.13)
Regulator outlet
Olive screw connection, 8 mm or 10 mm (H.9)
Recommended tightening torque
3 – 5 Nm for union nut M20 x 1.5 (G.13)
Horizontal triggering value
3.5 g ± 0.5 g
Operating temperature
‑30 °C to +50 °C
Declaration of conformity
The DuoControl CS gas pressure regulation system complies
with the pressure equipment directive 2014/68/EU, with the ap‑
plication of EN 16129:2013 and conforms to the UN ECE R122
Appendix VIII "Safety regulations for combustion equipment
and heating systems for liquid gas (LPG)". Complies with the
directive UN ECE R10 "Radio interference suppression in ve‑
hicles" and has the type approval number: E1 04 4352
Product ID number
CE‑0085BQ0102, DG approval number: 3894
Subject to technical changes.
18
)
di

Installation instructions

The unit may only be installed and re-
paired by an expert. Read the installation
instructions carefully before working, and
then comply with them!
Disregarding installation instruc-
tions or erroneous installation
can put people in danger and cause
damage to property.

Safety instructions

– Residual gas: No smoking, no naked flames!
– In the case of caravans and motor homes with 30 mbar
consumers, the maximum pressure loss ΔP of the down‑
stream installation to the consumer must not exceed
5 mbar (ΔP5).
– In order to ensure that the equipment operates correctly, the
gas pressure regulation system must be securely screwed
to a stable wall / ceiling (with 4 screws).
– Depending on the version, the DuoControl CS must be fit‑
ted to a stable wall in a vertical position or fitted to the top
of the gas cylinder box in a horizontal position. The trigger-
ing element (Figure 3 – A) must always be in a vertical
position.
– Attention must be paid to the installation position.