INSTALLATION
Adapting the cooker to another
type of gas.
This operation may only be carried out by an
appropriately authorised fitter.
If the gas the cooker is to be supplied with
differs from the gas provided for the cooker
by the manufacturer, that is G20 20 mbar,
burner nozzles must be exchanged and the
flame needs to be adjusted.
Somipress burner(marked „SOMI-
press" on the burner body)
Nozzle diameter
Auxiliary
Heat load
Gas consumption
Nozzle diameter
Medium
Heat load
Gas consumption
Nozzle diameter
Large
Heat load
Gas consumption
Nozzle diameter
Oven
Heat load
Gas consumption
In order to perform adjusting operations, take off the knobs. Adjusting elements of the oven
burner are accessible after drawing out the oven chamber floor.
In order to adapt the cooker to burn a different
type of gas, you should:
exchange nozzles (see tables below),
adjust the "economical" flame.
Caution!
The cookers provided by the manufacturer
have burners which are factory-adapted to
use the gas specified on their data plates and
guarantee cards.
G20 2E -
G30 3B/P -
20mbar
30mbar
G25 2L -
25mbar
mm
0,72
kW
1,00
g/h
-
mm
0,98
kW
1,80
g/h
-
mm
1,17
kW
2,80
g/h
-
mm
1,30
kW
2,80
g/h
-
81
Gas type
G30 3B/P -
50mbar
0,52
0,45
1,00
1,00
73
-
0,67
0,58
1,80
1,80
131
-
0,83
0,75
2,80
2,80
204
-
0,84
0,75
2,80
2,80
204
-
G25.3 2K -
25 mbar
0,71
1,00
-
0,98
1,80
-
1,17
2,80
-
1,30
2,80
-