The surround consists of the following parts
(Fig. 2):
Part
Designation
nation
1
Steel parts FS 173
2
Soapstone kit FS 173
3
Soapstone lower front
4
Soapstone upper front
5
Soapstone side lower left
6
Soapstone side middle L/R
7
Soapstone side upper L
8
Soapstone side upper R
9
Soapstone side lower right
10
Fireproof board
11
Mounting bracket soapstone right
12
Mounting bracket soapstone flat
13
Washer special M6 recessed
14
Screw recessed head M6x30
15
Steel kit for soapstone FS 173
16
Sector vent lower section
17
Sector vent upper section
18
Spacer
19
Hex nut with flange M6 DIN6923 B
20
Internal shield plate FS 173
21
Sector vent plate FS 173
Optional extras FS 173
25
Floor plate FS73/74/173 SE-NO
26
Floor plate FS73/74/173 GER
3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are fitted by a qualified installer (see
www.jotul.com for a complete list of dealers).
Any modifications to the product by the distributor, installer
or consumer may result in the product and safety features not
functioning as intended. The same applies to the installation of
accessories or optional extras not supplied by Jøtul. This may
also be the case if parts that are essential to the functioning
and safety of the fireplace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
All manuals and user guides at all-guides.com
3.1 Fire Prevention Measures
There is a certain element of danger every time you use
your fireplace. The following instructions must therefore be
Desig-
followed:
2
2
1
2
1
1
1
2
6
3
18
18
1
1
3.2 Floor
1
4
4
Foundation
1
Make sure that the foundation is strong enough to bear the
1
weight of the fireplace (110 kg + 274 kg).
We recommend the removal of any flooring that is not attached
to the foundation ("floating floors") beneath the installation.
1
1
Requirements for protection of wooden flooring
beneath the fireplace
The product has integrated floor protection and may therefore
be placed directly on a wooden floor.
Requirements for protection of combustible
floors in front of the fireplace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
For Norway: Minimum 300 mm in front of the door and width
at least the same as the door.
3.3 Walls
Distance to walls made of combustible materials - see Fig. 1 (Jøtul
FS 173).
The fireplace may be used with a semi-insulated flue pipe provided
the distances between the fireplace and walls made of combustible
materials are as shown in Fig. 1 (Jøtul FS 173).
NB: Ensure that furniture and other combustible materials are
not too close to the fireplace. Combustible materials must not
be placed within 1000 mm of the fireplace opening.
3.4 Ceiling
If the ceiling above the fireplace is made of a combustible
material, the minimum distance between the fireplace and
ceiling must be 650 mm. i.e. a minimum ceiling height of 2350
mm.
The minimum safety distances when installing and using the
fireplace are given in fig. 1.
Ensure that furniture and other flammable materials are not
too close to the fireplace. Flammable materials should not be
placed within 1 metre of the fireplace.
Allow the fire to burn out. Never extinguish the flames with
water.
The fireplace becomes hot when lit and may cause burns if
touched.
Only remove ash when the fireplace is cold. Ash can contain
hot embers and should therefore be placed in a non-
flammable container.
Ash should be placed outdoors or be emptied in a place where
it will not present a potential fire hazard