Télécharger Imprimer la page

Cristec CPS2 OEM 12V/25A Manuel D'utilisation page 18

Publicité

3.2.5 Load curve
Boost in ON position
With this setting the CPS2 OEM 12V/25A charger produces a 3-state load curve IUoU: Boost, Absorption, Floating.
Boost Phase: starts up automatically when the charger is turned on if the battery is flat. The current is then at maximum
output.
Absorption Phase: begins when the voltage has reached the maximum Boost level. The current level starts falling.
These two phases combined last a maximum of 4 hours. The current depends on how charged the battery is.
Floating Phase: starts after 4 hours. The voltage switches to the Floating value and the rated current continues to drop.
Boost in OFF position
With this setting, the CPS2 OEM 12V/25A charger produces a single-stage UI type load curve. It generates a constant
voltage, supplying the current required by the battery(ies). Recharging time depends on the state of the battery, being
longer than when the boost is in the ON position.
CPS2OEM25ADEB.doc
All manuals and user guides at all-guides.com
U out
charger
Boost
Absorption
U boost
U floating
4 Hrs
0
I out
charger
Boost
Absorption
I nom
4 Hrs
0
U out
charger
U floating
0
I out
charger
I nom
0
Floating
t
Floating
t
t
t
18

Publicité

loading